Enhanced electron transfer mediated detection of hydrogen peroxide using a silver nanoparticle– reduced graphene oxide–polyaniline fabricated electrochemical sensor†

Show simple item record

dc.contributor.author Vijay Kumar
dc.contributor.author Rajeev Kumar Gupta
dc.contributor.author Ravi Kumar Gundampati
dc.contributor.author Devendra Kumar Singh
dc.contributor.author Sweta Mohan
dc.contributor.author Syed Hadi Hasan
dc.contributor.author Manisha Malviya
dc.date.accessioned 2019-10-22T04:52:21Z
dc.date.available 2019-10-22T04:52:21Z
dc.date.issued 2017-12-06
dc.identifier.issn 20462069
dc.identifier.uri http://localhost:8080/xmlui/handle/123456789/404
dc.description.abstract The current study aims at the development of an electrochemical sensor based on a silver nanoparticle-reduced graphene oxide-polyaniline (AgNPs-rGO-PANI) nanocomposite for the sensitive and selective detection of hydrogen peroxide (H2O2). The nanocomposite was fabricated by simple in situ synthesis of PANI at the surface of rGO sheet which was followed by stirring with AEC biosynthesized AgNPs to form a nanocomposite. The AgNPs, GO, rGO, PANI, rGO-PANI, and AgNPs-rGO-PANI nanocomposite and their interaction were studied by UV-vis, FTIR, XRD, SEM, EDX and XPS analysis. AgNPs-rGO-PANI nanocomposite was loaded (0.5 mg cm-2) on a glassy carbon electrode (GCE) where the active surface area was maintained at 0.2 cm2 for investigation of the electrochemical properties. It was found that AgNPs-rGO-PANI-GCE had high sensitivity towards the reduction of H2O2 than AgNPs-rGO which occurred at -0.4 V vs. SCE due to the presence of PANI (AgNPs have direct electronic interaction with N atom of the PANI backbone) which enhanced the rate of transfer of electron during the electrochemical reduction of H2O2. The calibration plots of H2O2 electrochemical detection was established in the range of 0.01 μM to 1000 μM (R2 = 0.99) with a detection limit of 50 nM, the response time of about 5 s at a signal-to-noise ratio (S/N = 3). The sensitivity was calculated as 14.7 μA mM-1 cm-2 which indicated a significant potential as a non-enzymatic H2O2 sensor. © 2018 The Royal Society of Chemistry. en_US
dc.language.iso en en_US
dc.publisher Royal Society of Chemistry en_US
dc.title Enhanced electron transfer mediated detection of hydrogen peroxide using a silver nanoparticle– reduced graphene oxide–polyaniline fabricated electrochemical sensor† en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search in IDR


Advanced Search

Browse

My Account