A comparative Study of Aptasensor Vs Immunosensor for Label-Free PSA Cancer Detection on GQDsAuNRs Modifed Screen-Printed Electrodes

Show simple item record

dc.contributor.author Srivastava, Monika
dc.contributor.author Nirala, Narsingh R.
dc.contributor.author Srivastava, S. K.
dc.contributor.author Prakash, Rajiv
dc.date.accessioned 2018-09-06T06:15:31Z
dc.date.available 2018-09-06T06:15:31Z
dc.date.issued 2018-01-31
dc.identifier.issn 2045-2322
dc.identifier.uri http://localhost:8080/xmlui/handle/123456789/34
dc.description.abstract Label-free and sensitive detection of PSA (Prostate Specifc Antigen) is still a big challenge in the arena of prostate cancer diagnosis in males. We present a comparative study for label-free PSA aptasensor and PSA immunosensor for the PSA-specifc monoclonal antibody, based on graphene quantum dotsgoldnanorods (GQDs-AuNRs) modifed screen-printed electrodes. GQDs-AuNRs composite has been synthesized and used as an electro-active material, which shows fast electron transfer and catalytic property. Aptamer or anti-PSA has immobilized onto the surface of modifed screen printed electrodes. Three techniqu s are used simultaneously, viz. cyclic voltammetry (CV), diferential pulse voltammetry (DPV) and electrochemical impedence spectroscopy (EIS) to investigate the analytical performance of both PSA aptasensor and PSA immunosensor with its corresponding PSA antigen. Under optimum conditions, both sensors show comparable results with an almost same limit of detection (LOD) of 0.14 ng mL−1. The results developed with ptasensor and anti-PSA is also checked through the detection of PSA in real samples with acceptable results. Our study suggests some advantages of aptasensor in terms of better stability, simplicity and cost efectiveness. Further our present work shows enormous potential of our developed sensors for real application using voltammetric and EIS techniques simultaneous to get reliable detection of the disease en_US
dc.language.iso en_US en_US
dc.publisher Springer Nature en_US
dc.relation.ispartofseries Scientific Reports;
dc.subject Aptasensor en_US
dc.subject Immunosensor en_US
dc.subject Cancer Detection en_US
dc.subject Electrodes en_US
dc.title A comparative Study of Aptasensor Vs Immunosensor for Label-Free PSA Cancer Detection on GQDsAuNRs Modifed Screen-Printed Electrodes en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search in IDR


Advanced Search

Browse

My Account