Effect of Ultrasonic shot Peening on microstructure corrosion and low cycle fatigue behavior of the alloy Ti 6Al 4V

Show simple item record

dc.contributor.author Kumar, Sanjeev
dc.date.accessioned 2023-05-10T06:31:55Z
dc.date.available 2023-05-10T06:31:55Z
dc.date.issued 2016
dc.identifier.uri http://localhost:8080/xmlui/handle/123456789/2338
dc.description.abstract Ti–6Al–4V alloy is used for wide applications such as chemical and aerospace industries due to high specific strength. It is also used in orthopaedic and dental bio-implants because of their excellent biocompatibility and corrosion resistance in physiological environments due to formation of protective oxide layer of TiO2. It has dual phase microstructure with primary α and transformed β. The Al is support to α phase however; V is β phase stabilizer element at room temperature. en_US
dc.language.iso en en_US
dc.subject Ultrasonic en_US
dc.subject Microstructure en_US
dc.title Effect of Ultrasonic shot Peening on microstructure corrosion and low cycle fatigue behavior of the alloy Ti 6Al 4V en_US